Most appropriate location for information processing facilities in a 6-stories building.

Floor Selection for Information Processing Facilities.

Prev Question Next Question

Question

Which of the following floors would be most appropriate to locate information processing facilities in a 6-stories building?

Answers

Explanations

Click on the arrows to vote for the correct answer

A. B. C. D.

C.

You data center should be located in the middle of the facility or the core of a building to provide protection from natural disasters or bombs and provide easier access to emergency crewmembers if necessary.By being at the core of the facility the external wall would act as a secondary layer of protection as well.

Information processing facilities should not be located on the top floors of buildings in case of a fire or flooding coming from the roof.Many crimes and theft have also been conducted by simply cutting a large hole on the roof.

They should not be in the basement because of flooding where water has a natural tendancy to flow down :-)Even a little amount of water would affect your operation considering the quantity of electrical cabling sitting directly on the cement floor under under your raise floor.

The data center should not be located on the first floor due to the presence of the main entrance where people are coming in and out.You have a lot of high traffic areas such as the elevators, the loading docks,cafeteria, coffee shopt, etc..Really a bad location for a data center.

So it was easy to come up with the answer by using the process of elimination where the top, the bottom, and the basement are all bad choices.That left you with only one possible answer which is the third floor.

Source: HARRIS, Shon, All-In-One CISSP Certification Exam Guide, 5th Edition, Page 425.

When determining the appropriate location for information processing facilities within a multi-story building, several factors should be taken into consideration, including accessibility, security, infrastructure, and potential environmental hazards.

Given a 6-stories building, the most appropriate floor to locate information processing facilities would depend on several factors, including the building's structure and layout, the business's specific needs, and the security measures in place.

Here are some considerations for each option:

A. Basement: The basement may seem like an ideal location for an information processing facility as it provides a certain level of security from external threats, such as physical attacks or natural disasters like earthquakes. However, basements may be susceptible to environmental hazards like flooding, and they may not have adequate ventilation or cooling systems. In addition, basements may not be easily accessible to the rest of the building, and moving equipment and personnel up and down the stairs could be challenging.

B. Ground floor: The ground floor may offer easy accessibility for personnel and equipment, and it may have adequate infrastructure, such as power and networking. However, it may be vulnerable to external threats like break-ins or natural disasters, and it may be challenging to maintain privacy and security from the public. Ground floors may also be subject to more traffic, noise, and other distractions that could impact productivity.

C. Third floor: The third floor may offer some of the benefits of the ground floor, such as accessibility and infrastructure, but with added security and privacy. It is high enough to be less vulnerable to external threats, and it is typically less busy than the ground floor, which could minimize distractions. However, depending on the building's layout, the third floor may be challenging to access, and it may require additional security measures to ensure the safety of equipment and personnel.

D. Sixth floor: The sixth floor is the highest level of the building, which may offer added security and protection from external threats. It is also typically less busy than the lower floors, which could minimize distractions and improve productivity. However, the sixth floor may be challenging to access, especially in the event of an emergency or equipment failure. It may also require additional infrastructure, such as elevator systems or backup power, to ensure its functionality.

In conclusion, the most appropriate floor to locate information processing facilities in a 6-stories building would depend on several factors, including accessibility, security, infrastructure, and potential environmental hazards. The third floor may offer the best balance of these factors, but the decision ultimately depends on the specific needs and requirements of the business.